Products & Tech
To help you accelerate your debugging workflow, we have compiled this FAQ regarding our products and technologies. Whether you are troubleshooting high-speed signals or integrating complex protocol decoders, our resources are designed to support your success. If you have any other needs, please feel free to contact our technical and business teams for further consultation.
Q: What is the maximum input voltage for the logic analyzer?
A: The LAP-C Pro supports an input range of ± 30V, while the LAP-F1 is designed for high-speed signals with a range of ± 10V.
Q: What should I do if my signal voltage exceeds 30V?
A: Do not connect the logic analyzer directly. You must use a voltage divider circuit or an attenuator to step down the voltage to within the instrument's safe operating range before measurement.
Q: What is the Trigger Level?
A: The Trigger Level is the Level Line which is provided for the Logic Analyzer to judge the High and Low Levels of the signal; when the input signal voltage is higher than the Trigger Level, the Logic Analyzer will judge the signal as High Level; when the signal voltage is lower than the Level Line, it will be judged as Low Level.
Q: How do we deal with it when the measured signal is different from the oscilloscope's, and has much noise?
A: This is usually due to an incorrect Trigger Level setting. Set the threshold to half of the signal voltage (e.g., for a 1.8V signal, set the threshold to 0.9V). If the signal exceeds the default -6V to +6V range, use an oscilloscope to verify the actual voltage before manually inputting the threshold, ensuring it remains within the maximum rated input voltage.
Q: The range of Trigger Level is from 6V to -6V; if the voltage is 18V, How do I set?
A: You can set the trigger level to 6V. This will allow you to determine the high and low levels. Note that the LAP-F1 cannot measure signals exceeding 10V.
Q: Why is negative voltage level adjustment provided?
A: Providing more flexible level adjustment makes it easier for users to analyze various signals.
Q: Do you have the Logic Analyzer with a higher Level? Is there a higher Sampling Frequency?
A: Our flagship model is the LAP-F1. It achieves a maximum sampling rate of 2GHz (Timing Analysis) across 32 channels. To ensure signal fidelity at these speeds, it must be used with the P300ST Active Probe. Contact us for a live demo or technical consultation.
Q: What is Internal Sampling (Timing Analysis)?
A: Since the sampling clock and tested objects are not directly related to each other, and the former won’t be controlled by the latter, the sampling clock and the tested signals will not be done at the same time. We call this "Timing Mode", which means that in the same time interval (the sampling time is 1/Sampling Frequency), you can get sampling data from the test equipment at one time, for example, sampling the data from the test equipment every 5ns (the sampling frequency is 200MHz).
Q: What is External Sampling (State Analysis)?
A: Because the sampling clock and measured object can be directly related, and are controlled by the latter, signals of the former and the latter can proceed simultaneously. We call this "State Mode". In this mode, the measured object provides the sampling clock. State Mode is that the Logic Analyzer can obtain sampling data from the test equipment synchronously. In other words, when the test equipment has a signal or signal group, it is the time to get the signal. For example, while the test equipment is sending out one Rising Edge, the Logic Analyzer can start to obtain one signal.
Q: What is the Bar?
A: Similar to oscilloscope cursors, used to calculate the time difference between two points on a waveform.
Q: What is the T-Bar?
A: It is Trigger Bar, Indicates the exact moment the Trigger Condition was met. It serves as the Time Zero (0s) reference for all captured data.
Q: Can the "Analog Waveform" feature display sine waves?
A: Yes. The software reconstructs waveforms based on Parallel Bus values. If the digital data represents a sine wave or audio signal, the software will render the corresponding analog-like curve.
Q: Why does the Analog Waveform feature require at least 4 channels?
A: To provide a meaningful visual representation, at least 4 bits (16 levels of resolution) are required. Using fewer channels results in a blocky "trapezoidal" wave, which loses the utility of analog visualization.
Q: Can I decode the MISO and MOSI at the same time?
A: Yes. The ZP-Logic software (used by LAP-C Pro and LAP-F1) allows users to group MISO and MOSI into a single bus for simultaneous, dual-direction protocol decoding, streamlining your SPI interface debugging.