RC-6 Infrared Remote Protocol Analysis (Philips)

RC-6 infrared remote protocol decoder configuration

Application Field: IR Remote Control

Philips RC-6 Protocol Analysis for IR

RC6 Infrared Remote Control Format, developed by Philips, is a new infrared remote control signal protocol. And it is similar to RC5 in the structure. Philips RC6 Remote Control Signal utilizes 36K carrier. A bit of information, which is transmitted each time, occupies 32 carrier periods (about 889us). The time transmitted by infrared and the idle time occupies half of the carrier period (444US) respectively. That is to say, the time transmitted by the infrared signal is 16 carrier periods, and the idle time is also 16 carrier periods. If the transmission time is previous to the idle time, it indicates that the transmitted value is "1"; if the idle time is previous to the transmission time, it indicates that the transmitted value is "0".


With Zeroplus logic analyzers and Philips RC-6 analysis capability, engineers can capture, decode, and interpret infrared packets and baud rate settings more efficiently for remote-control device validation, signal debugging, and home appliance control analysis.

Function Introduction

Protocol Analyzer Philips RC-6 Decoding Module of Zeroplus Technology can analyze the packets in the Transmission Control Signal of Philips RC-6, such as LEADER, START, MODE, TOGGLE0, TOGGLE1, ADDRESS and COMMAND. In the Protocol Analyzer Philips RC-6 Decoding Module of Zeroplus Technology, the packets in the signal can be displayed with the graphical mode, which can improve the working efficiency and save the time of calculating the decoding by hand. At the same time, Protocol Analyzer Philips RC-6 Decoding Module of Zeroplus Technology can judge the Baud Rate in the signal automatically, which is convenient for analyzing the signal.

  • Channel Name: Philips RC-6
  • Frequency: RX: 1125Hz / TX: 36KHz
  • Application Field: IR Remote Control
Gallery
Download

Philips RC-6 Protocol Analysis for IR

  • Display:
Result 1 - 10 of 10
40 Channels High Speed Logic Analyzer - 1Gb Deep Memory and Exclusive USB 3.0 Lossless Streaming Technology: The Ultimate Solution for Mid-to-High Complexity Digital Debugging.
40 Channels High Speed Logic Analyzer
LAP-F140512M | FM00006147

The 40-channel High-Speed Logic Analyzer: Engineered for synchronized multi-bus measurement...

Details
64-Channel Synchronous Logic Analyzer - The 64-channel synchronous logic analyzer is the premier solution for digital system verification requiring simultaneous observation of massive signal pins and multi-bus states.
64-Channel Synchronous Logic Analyzer
LAP-F164064 | FM00002619

Harnessing a 64-channel synchronous monitoring core, this system supports internal timing sampling...

Details
64-Channel Advanced Logic Analyzer - Featuring a 64-channel synchronous monitoring architecture and 256M per-channel memory depth, this model perfectly balances high-density multi-bus measurement with extensive data logging capabilities.
64-Channel Advanced Logic Analyzer
LAP-F164256M | FM00006156

The 64-Channel Advanced Logic Analyzer stands as a perfectly balanced model, integrating 64-channel...

Details
16-Channel Entry-Level High-Performance Logic Analyzer - Support Ultra-High Sampling Rates
16-Channel Entry-Level High-Performance Logic Analyzer
LAP-C Pro 16064M | FM00007890

The 16-Channel High-Performance Logic Analyzer is ideal for digital development tasks requiring...

Details
32-Channel High-Performance Logic Analyzer - The 32-Channel High-Performance Logic Analyzer is ideal for digital system verification tasks that require an increased number of synchronous observation channels and high-speed sampling capabilities.
32-Channel High-Performance Logic Analyzer
LAP-C Pro 32064M | FM00007893

The 32-Channel High-Performance Logic Analyzer is ideal for digital system verification tasks...

Details
32-Channel Advanced High-Performance Logic Analyzer - The 32-Channel Advanced High-Performance Logic Analyzer is ideal for development and verification tasks.
32-Channel Advanced High-Performance Logic Analyzer
LAP-C Pro 32128M | FM00007896

The 32-Channel Advanced High-Performance Logic Analyzer is ideal for development and verification...

Details
32-Channel Flagship High-Performance Logic Analyzer - The 32-Channel Flagship High-Performance Logic Analyzer is ideal for advanced development environments.
32-Channel Flagship High-Performance Logic Analyzer
LAP-C Pro 32256M | FM00007899

The 32-Channel Flagship High-Performance Logic Analyzer is ideal for advanced development environments...

Details
16-Channel Standard Logic Analyzer - Each channel features 64Kb memory depth, delivering reliable performance for microcontroller and embedded system debugging.
16-Channel Standard Logic Analyzer
LAP-C 16064 | FM00000118

The 16-channel standard logic analyzer is ideal for daily debugging needs such as microcontroller...

Details
16-Channel Enhanced Logic Analyzer - Each channel features 128Kb memory depth, delivering reliable performance for microcontroller and embedded system debugging.
16-Channel Enhanced Logic Analyzer
LAP-C 16128 | FM00000116

The 16-channel enhanced logic analyzer is designed for embedded development, digital debugging,...

Details
ProCision System Stability Analyzer - Smart Pair Analysis: Automatically calculates intervals between signals (e.g., 5VSB to AUX_PCTL or PWRBTN# to V1P8A).
ProCision System Stability Analyzer
FM00011874

The ProCision is a high-density system stability analyzer engineered to replace limited 4-channel...

Details
Result 1 - 10 of 10

Reading RC-6 Leader and Mode Fields

RC-6 is the newer Philips infrared format, also among the Zeroplus infrared decoder options. It is similar in structure to RC-5 but adds a leader and a mode field, which identifies the RC-6 variant in use; the RC-6 decoder is specified for a 36KHz transmit carrier.

The Zeroplus RC-6 decoder labels LEADER, START, MODE, TOGGLE0, TOGGLE1, ADDRESS and COMMAND, and sets the baud rate automatically, which simplifies receiver testing without manual configuration. This helps when checking remote controls, receivers and appliance control boards, where a wrong mode or address explains why a key press is ignored. For the older format, see RC-5 decoding; the same analyzer handles both, which simplifies selection.