MII Protocol Analysis for Ethernet
The MII is one of the interfaces in the IEEE802.3U of the Ethernet Technology Specifications, which is divided into the MII Data Transmission and the MII Management Information. SMI (Serial Management Interface) is the important part in the MII. The interface, which is not relative with the transmission medium, is supplied through the MII, which is convenient for the Ethernet to change the medium. It is applied for the PC NIC, Ethernet Router or the ARM Micro-Control (EP93XX Serial, ARM9).
Function Introduction
MII needs 18 signal lines to transmit the data, the frequency is from 2.5MHz to 25MHz. The signal pins are as below:
● MDIO: Management Data Input / Output
● MDC: Management Data Clock
● TX_CLK/RX_CLK: Transmit Clock / Receive Clock
● TX_ER/RX_ER: Transmit Error / Receive Error
● TX_D0/RX_D0: Transmit Data0 / Receive Data0
● TX_D1/RX_D1: Transmit Data1 / Receive Data1
● TX_D2/RX_D2: Transmit Data2 / Receive Data2
● TX_D3/RX_D3: Transmit Data3 / Receive Data3
● TX_EN: Transmit Enable
● RX_DV: Receive Data Valid
● COL: Collision
Detected By way of using the Protocol Analyzer MII of Zeroplus Logic Analyzer, it will help you improve the working efficiency of signal analysis. In the digital times, more and more signals are transmitted through the digital mode. According to the Protocol Analyzer Analysis Module of Zeroplus Logic Analyzer, engineers can make more convenient choices when analyzing the digital signals. The packets( Data, Address and Status) of the Protocol Analyzer can be displayed with the graphical mode on the PC, which can let engineers get the analysis result quickly, improve the working efficiency and shorten the time of development.
- Bus Line: MDIO, MDC, TX_CLK/RX_CLK, TX_ER/RX_ER, TX_D0/RX_D0, TX_D1/RX_D1, TX_D2/RX_D2, TX_D3/RX_D3, TX_EN, RX_DV, COL
- Frequency: 2.5MHz ~ 25MHz
- Voltage: 3.3V
- Area of Project Application: Ethernet System Interface
- Gallery
- Download
-
40 Channels High Speed Logic Analyzer
LAP-F140512M | FM00006147
The 40-channel High-Speed Logic Analyzer: Engineered for synchronized multi-bus measurement...
Details64-Channel Synchronous Logic Analyzer
LAP-F164064 | FM00002619
Harnessing a 64-channel synchronous monitoring core, this system supports internal timing sampling...
Details64-Channel Advanced Logic Analyzer
LAP-F164256M | FM00006156
The 64-Channel Advanced Logic Analyzer stands as a perfectly balanced model, integrating 64-channel...
Details16-Channel Entry-Level High-Performance Logic Analyzer
LAP-C Pro 16064M | FM00007890
The 16-Channel High-Performance Logic Analyzer is ideal for digital development tasks requiring...
Details32-Channel High-Performance Logic Analyzer
LAP-C Pro 32064M | FM00007893
The 32-Channel High-Performance Logic Analyzer is ideal for digital system verification tasks...
Details32-Channel Advanced High-Performance Logic Analyzer
LAP-C Pro 32128M | FM00007896
The 32-Channel Advanced High-Performance Logic Analyzer is ideal for development and verification...
Details32-Channel Flagship High-Performance Logic Analyzer
LAP-C Pro 32256M | FM00007899
The 32-Channel Flagship High-Performance Logic Analyzer is ideal for advanced development environments...
Details16-Channel Standard Logic Analyzer
LAP-C 16064 | FM00000118
The 16-channel standard logic analyzer is ideal for daily debugging needs such as microcontroller...
Details16-Channel Enhanced Logic Analyzer
LAP-C 16128 | FM00000116
The 16-channel enhanced logic analyzer is designed for embedded development, digital debugging,...
DetailsProCision System Stability Analyzer
FM00011874
The ProCision is a high-density system stability analyzer engineered to replace limited 4-channel...
DetailsDecoding the Ethernet MAC/PHY Interface
MII connects an Ethernet MAC to its PHY in network equipment. The MDIO and MDC management pair configures the PHY while the TX and RX paths carry frames, so link problems can come from PHY configuration or from the data path. The decoder uses MDIO, MDC, TX/RX clock, TX/RX error, TX/RX data 0 to 3, TX_EN, RX_DV and COL, and displays data, address and status.
Capturing the data lines together with MDIO shows which side a fault sits on. Full MII uses 17 lines, more than a 16-channel model offers, so plan on a 32-channel LAP-C Pro or a LAP-F1. For tapping a 10/100 link at its RJ45 connector, the Ethernet module provides an MII interface; check its compatibility with your analyzer model before selection.